Skip to main content

Pt100 EKB and ELB

Temperature Sensor With Fixed RTD Element and ½" Connection Series EKB and ELB PT100's

pt100 ekbelb

Manufactured by  emco controls

Principle

EMCO temperature sensors >series EKB and ELB are used for temperature measurement within many industries including in steel works, power stations, chemical and petro-chemical industries, pharmaceutical and food industry, cement factories and marine industry etc.

Construction

  • The sensing element consists of a ceramic plate with platinum fixed to it according to the thin film technique. The electrical resistance changes with the temperature. The resistance is 100 ohm at 0°C.
  • Due to the small weight of the sensing element, 2 things are secured :
  • Short response time and insensitive to vibrations.
  • Connecting Head:Type B according to DIN 43729 standard in aluminium IP 55, option stainless steel IP 65, plastic with threaded cover, aluminium with threaded cover
  • Sensor :Pt100 according to IEC 751
  • No. of sensors :1 or 2
  • Well OD :8 mm
  • Well material :Stainless steel AISI 316Ti (1.4571).
  • Process connection :½" BSP P thread
  • Accessories :Temperature transmitter 2 wire 4-20 mA, HART communication, Profibus PA, Foundation fieldbus EEx ia IIC T4/T6 for hazardous areas

Technical Data

  • Max. working pressure :50 bar
  • Max fluid velocity :Gasses 25 m/s, liquid 3 m/s
  • Temperature range :-50 + 400°C. Outside these limits wire wound sensors are to be used
  • Accuracy :± 0,3 + 0,005 x t where t is the temperature in °C (class B) higher accuracies are available class A, 1/2 DIN, 1/3 DIN 1/6 DIN on request
  • Electrical connection :PG 16 for type B and plastic head, PG 16, M20, ½"NPT for stainless steel and threaded aluminium head

Dimensions

Type Insertion length L Type Insertion length L
EKB1 50 mm ELB1 50 mm
EKB2 100 mm ELB2 100 mm
EKB3 150 mm ELB3 150 mm
EKB4 200 mm ELB4 200 mm
EKB5 300 mm ELB5 300 mm
EKB6 400 mm ELB6 400 mm
EKB7 500 mm ELB7 500 mm

pt100 elb8mmpt100 ekb8mm

 

Download Datasheet (Not Available) Download Manual (Not Available)

If you require further information on this product or would like a quotation, please contact dp-flow on:

Supplied by DP-Flow