Classical venturi tubes are used as primary elements in flow measurement of steam, liquid and gas according to the differential pressure principle.

Design standards :

  • ISO 5167-4 and ASME MFC-3M
  • Sizes : DN 100 - 800 according to ISO 5167
  • Bore/diameter (β) : 0,3 ≤ β ≤ 0,75
  • Pressure rating : PN 10 - 640, 150 - 2500 lbs, ISO PN 20 –420
  • Material : Carbon steel, AISI 316, others on request
  • Mounting style : Weld ends according to DIN 2559 or ANSI B16.25. Flanges acc. to DIN or ANSI B16.5 standards or Clamp connections like Grayloc
  • Pressure taps : Weld ends Ø 21.3 mm, 26.9 mm, thread connection 3/8", 1/2" BSP, 1/2" NPT
  • Tappings : Single pressure tappings or 4x2 tappings each arranged with an external annular ring to equalise the pressure
  • Outlet cone : 7 - 15°

Technical Data

  • Accuracy : 0,7 % (according to ISO 5167-4)
  • Pressure loss : Depending on outlet cone between 10 - 15 % of the differential pressure measured
  • Limits for Re. No. : 2 x 10 5 < ReD < 2 x 10 6
  • Accessories : Shut-off valves and condensing chambers for steam flow.

venturi-classical tap

venturi classical kvr

Works with:-

Differential pressure transmitters:-IDP10; IDP15; IDP25; IDP31; IDP50
And all our Absolute Pressure and Gauge Pressure transmitters, Temperature sensors and mass flow computers.