Skip to main content

Orifice Plates Series ISB/2

Orifice Plate Series with Integrated Unit for RTJ Flanges ISB/2

orifice

Manufactured by  emco controls

The EMCO compact orifice

Design and calculation standards :

  • ISO 5167, ASME MFC-3M, ISA RP 3.2, Shell Flow Meter Engineering Handbook, L. K. Spink, AGA no. 3
  • Sizes : 1" - 20" according to ANSI B 16.36, 50 mm < D < 1000 mm according to ISO 5167 and 50 mm < D < 900 mm according to ASME MFC-3M.
  • Bore (d) : d > 12,5 mm
  • β (d/D) : 0,2 < β < 0,75
  • Plate thickness : 3 - 9 mm
  • Holder width : 27 mm; * 28.5, ** 30 mm, *** 32 mm.
  • Material : Carbon steels, AISI 316, Monel, 6Mo and others on request
  • Vent or drain hole : On request
  • Mounting style : Between RTJ flanges according to ANSI B16.36, API, other standards on request.
  • Holder type : Oval or octagonal.
  • Orifice plate shapes : Square edge concentric, square edge eccentric, conical, 1/4 circle, segment.
  • Handle : With name plate in AISI 316 with the following inscription : TAG no., serial no., pressure rating, inner pipe dia., bore, material.

Orifice ISB2 RJT GA

orifice plate shapes

Size

Size Pressure rating lbs   
  600 900 1500 2500
1" R16   R16 R18
11⁄2” R20   R20 R23
2" R23   R24 R26
21⁄2” R26   R27 R28**
3" R31 R31 R35 R32**
4" R37 R37 R39  
6" R45 R45 R46*  
8" R49 R49    
10" R53 R53    
12" R57 R57    
14" R61      
16" R65***     *
18" R69***      
20" R73***      

Works with:-

Differential pressure transmitters:-IDP10; IDP15; IDP25; IDP31; IDP50
And all our Absolute Pressure and Gauge Pressure transmitters, Temperature sensors and mass flow computers.
MultiVariable Transmitters :- IMV25, IMV30

 
Download Manual (Not Available)

If you require further information on this product or would like a quotation, please contact dp-flow on:

Supplied by DP-Flow