Skip to main content

Multi Hole Compact Orifice

Multi Hole Compact Orifice

epsilon compact mount conditioning orifice plate

The Multi Hole Compact Orifice flow meter measuring most liquids and gases. The meter is a conditioning flow orifice assembly designed to slip between DIN and ANSI flanges, and is designed for compact mounted dp cells. With an installation length of 32mm it can be installed in existing systems simply and easily, and incorporates the dp flow priciple. d/p metering enables easy re-calibration routines for process operators, negating the need for expensive flow metering spares and external flow recalibration services.

Benefits

  • Sizes ranging from DN 40 (1½") up to DN 400 (16").
  • Designed for limited space installations, flow conditioning effect created by the 5 hole design.
  • No moving parts.
  • Not sensitive to vibrations.
  • Compact design.
  • Easy to install.
  • High accuracy.

Typical Applications

The Multi Hole Compact Orifice flow meters measure the flow of most liquids and gases within the process industries, including chemical, petrochemical, phamacutical and the power industry. The Multi Hole Compact Orifice is especially designed for installations with limited space due to the flow conditioning effect created by the 4 hole design. It is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric. The flow meters are based on international standards and private information covering flow calculation, manufacturing tolerances, accuracy and installation requirements. This new type of 'fundamental' technology increases the number of potential successful applications for DP flow meters in world.

The flow meter features are:

  • VERY short straight pipe run requirement
  • Standardised product based on well proven technology.
  • Compact design.
  • Simple construction.
  • Free choice for horizontal or vertical pipe run.
  • Standardised construction means low inventory.
  • No moving parts.
  • Not sensitive to vibrations.
  • The electronics delivers output signal linear to flow.
  • Digital indicator for local flow reading.
  • High accuracy.
  • Wide rangeability.
  • Easy to install.
  • Easy to re-calibrate.

epsion EP2 EP1

 

Construction

The standard for primary elements ISO 5167-1 describes different types of flow conditioners (flow straighteners) avaiable. These elements are inserted up stream the flow meter to improve the flow profile.
The 4 hole flow meter combines a traditional single hole orifice plate with a flow conditioner. This reduces the straight pipe run up stream of the flow meter, which can be  reduced from 20 times inner pipe diameter to 2 times inner pipe diameter.

Model Multi Hole Compact Orifice

The Multi Hole Compact Orifice flow meter model consists of a primary element based on the differential pressure principle with an integrated 3 valve manifold valve and an electronic differential pressure transmitter with digital signal processing.
The flow meter is mounted between flanges in sizes from DN 40 (11⁄2") to DN 400 (16") in pressure ratings up to PN 40 (300 lbs).

remote mount kit rmk

Accessories

Remote Mounting Kits are available if remote mounting of electronics is required in case of difficulty accessing the pipeline or if there are elevated process temperatures.
The customer has to provide the stainless steel instrument tube Ø 12 x 1 mm between flow meter and electronics. Remote electronic indicator with LCD is available for local flow indication and if required check/change of flow rate (differential pressure).

Principle of measurement

The Multi Hole Compact Orifice is a velocity flow meter. A restriction in a pipe line changes the value of respective momentum energy, in terms of static and dynamic pressure. Based on the laws of energy balance developed by Bernoulli, the sum of the energies remain constant. Increasing the velocity in the pipe line, decreases the pressure in the restriction. The pressure differential between the inlet pressure and the pressure in the restriction is measured and expressed as flow velocity. When the physical values of the fluid are known and the inner pipe diameter is established the electronics calculates the flow rate. The flow rate is expressed in an analogue signal 4 - 20 mA signal or via digital communication.

Technical data

  • Sizes : DN 40 - DN 400, 11⁄2" - 16", larger sizes on request
  • Pressure rating : up to PN 40, 300 lbs, higher pressure ratings on request
  • Temperature : Process : -50 - +150°C,
  • higher temperature with Remote Mounting Kit
  • Mounting style : Between flanges according to DIN or ANSI standards
  • Flange facing : flat face (standard), raised face, DIN 2512 N, DIN 2513 R
  • Overall length : 32 mm
  • >Material : Stainless steel AISI 316, others on request
  • Design and calculation standards : ISO 5167, ASME MFC-3M.
  • Vent or drain hole : On request
  • β (d/D) : 0,5 and 0,6; other β on request.
  • Accuracy : +/- 1 %
  • Rangeability : 8:1
  • >Repeatability : better than 0,1 %
  • Pressure loss : typical 150 mbar for liquid flow, and 50 mbar for gas flow (values are given at full flow)
  • Reynolds No : Re > 5000
  • Allowable differential pressure : max 2,5 bar
  • Output signal : analogue 4 - 20 mA or Digital communication via protocol, HART, PROFIBUS, Fieldbus Foundation or others.
  • Local indicator (option): LCD showing flowing units or %
  • Power supply : 14 - 36 Vdc, typical 24 Vdc.
  • Max load (24 Vdc) : 700 Ohm
  • Enclosure : IP 67
  • Ex protection : intrinsically safe EEx ia IIC T6,Explosion proof EEx d IIC T6
  • Temperature : Ambient : -40 - +80°C

Sizes

DIN flanges

Size Pipe OD Pressure rating Inner pipe diameter ß = 0,5 Bore ß = 0,6 Bore B A1 A2
DN 40 48,3 PN 40 43,1 21,5 26,0 90 147 157
DN 50 60,3 PN 40 54,5 27,3 32,0 107 156 166
DN 65 76,1 PN 40 70,3 35,0 42,0 127 166 176
DN 80 88,9 PN 40 82,5 41,0 49,5 142 173 183
DN 100 114,3 PN 16 107,1 54,0 64,0 162 183 193
DN 100 114,3 PN 40 107,1 54,0 64,0 168 186 196
DN 125 139,7 PN 16 131,7 66,0 79,0 192 198 208
DN 125 139,7 PN 40 131,7 66,0 79,0 194 199 209
DN 150 168,3 PN 16 159,3 80,0 96,0 218 211 221
DN 150 168,3 PN 40 159,3 80,0 96,0 224 214 224
DN 200 219,1 PN 16 207,3 104,0 124,4 273 239 249
DN 200 219,1 PN 25 206,5 104,0 124,4 284 244 254
DN 200 219,1 PN 40 206,5 104,0 124,4 290 247 257
DN 250 273 PN 16 260,4 130,0 156,0 329 267 277
DN 250 273 PN 25 258,8 130,0 156,0 340 272 282
DN 250 273 PN 40 258,8 130,0 156,0 352 278 288
DN 300 323,9 PN 10 309,7 155,0 185,0 378 291 301
DN 300 323,9 PN 16 309,7 155,0 185,0 384 294 304
DN 300 323,9 PN 25 307,9 155,0 185,0 400 302 312
DN 300 323,9 PN 40 307,9 155,0 185,0 417 311 321
DN 350 355,6 PN 10 341,4 170,0 204,0 438 321 331
DN 350 355,6 PN 16 339,6 170,0 204,0 444 324 334
DN 350 355,6 PN 25 339,6 170,0 204,0 457 331 341
DN 350 355,6 PN 40 338,0 170,0 204,0 474 339 349
DN 400 406,4 PN 10 392,2 195,0 234,0 489 341 351
DN 400 406,4 PN 16 390,4 195,0 234,0 495 350 360
DN 400 406,4 PN 25 388,8 195,0 234,0 514 359 369
DN 400 406,4 PN 40 384,4 195,0 234,0 546 375 385

ANSI Flanges

Size Pipe OD Pressure rating Sch. 10S Inner pipe dia. Sch. 40 Inner pipe dia. Sch. 80 Inner pipe dia. ß=05 Bore. ß=06 Bore. B A1 A2
11⁄2" 48,3 150lbs 42,7 40,9 37,3 20,0 24,0 85,7 145 155
    300lbs           95,3 150 160
2" 60,3 150lbs 54,7 52,5 49,3 26,0 31,5 104,8 154 164
    300lbs           111,1 158 168
3" 88,9 150lbs 82,8 77,9 73,7 39,0 47,0 136,5 170 180
    300lbs           149,1 177 187
4" 114,3 150lbs 108,2 102,3 97,2 51,0 61,0 174,6 189 199
    300lbs           181,1 193 203
6" 168,3 150lbs 161,5 154,1 146,3 77,0 92,5 222,3 213 223
    300lbs           279,4 242 252
8" 219,1 150lbs 211,5 202,7 193,7 101,0 121,6 279,4 242 252
    300lbs           308 256 266
10" 273 150lbs 264,6 254,5 242,8 127,0 153,0 339,7 272 282
    300lbs           362 283 293
12" 323,9 150lbs 314,7 303,2 289,1 150,0 180,0 409,6 307 317
    300lbs           422,3 313 323
14" 355,6 150lbs 346 333,3 317,5 165,0 198,0 450,9 327 337
    300lbs           485,8 345 355
16" 406,4 150lbs 396,8 381 363,6 190,0 228,0 514,4 359 369
    300lbs           539,8 372 382

Overall Dimensions 

epsilon ga

Installation requirements

The Multi Hole Compact Orifice flow meter can be mounted in a horizontal or vertical pipe. For liquid flow in a horizontal pipe the electronics shall be mounted below the pipe. For gas flow in a horizontal pipe the electronics shall be mounted above the pipe. High accuracy of measurement is achievable even with short straight pipe runs up-stream from the flow meter. The required straight pipe run is only 2 x inner pipe diameter and 2 x downstream to maintain an accuracy of 2%. If mass flow required due to changing process conditions ask for the mass flow meter data sheet. Saturated and superheated steam is covered by the Multi Hole Compact Orifice flow meters

Works with:-

Differential pressure transmitters:-IDP10; IDP15; IDP25; IDP31; IDP50
And all our Absolute Pressure and Gauge Pressure transmitters, Temperature sensors and mass flow computers.
MultiVariable Transmitters :- IMV25, IMV30

Download Manual (Not Available)

 

If you require further information on this product or would like a quotation, please contact dp-flow on:

Supplied by DP-Flow