Venturi Tubes shipped off

The flow meters were supplied for the two separate streams on the outlet of two dryers. They included mass flow correction (pressure and temperature compensation) and water content analysis.

VENTURI DN250 KVR

The clients objective was to supply flow control ensuring optimum energy efficiency on a drying process, reducing energy demand on the heat input. Transmitters for each line included an absolute pressure transmitter, temperature sensor (4 wire RTD) and a differential pressure transmitter. These all fed back into the clients mass flow control system that incorporated humidity analysers and an out mass flow for flow control.

The venturi tube flow meters were supplied flow calibrated, with EN 10204-3.1 material certificates,  ISO 5167 calculations (CONVAL 9) full drawings and documentation packs.