Skip to main content

z-IAP10

Intelligent Absolute Pressure Transmitters IAP10

IGP10

Manufactured byfoxboro

The Foxboro absolute pressure transmitter IAP10 is an intelligent, two-wire transmitter provides precise, reliable, measurement of absolute pressure and transmit a 4 to 20 mA output signal with a superimposed HART® digital signal for remote configuration and monitoring.
Remote seals are required for operation and mounting. See Remote Seals for Pressure Transmitters

Key Benefits

  • Simple, elegant sensor packaging uses very few parts to achieve exceptionally high reliability
  • Liquid Crystal Display (LCD) digital indicator with on-board pushbutton configuration and calibration.
  • NEMA 4X and IEC IP66 durable epoxy-coated aluminum, or 316 ss housings.
  • Co-Ni-Cr, 316L ss, and Nickel alloy (equivalent to Hastelloy®(1)) sensor materials for all transmitters.
  • Can be provided with numerous configurations of direct connect or remote mount seals.
  • Integral process connections for sanitary, and pulp/paper installations.
  • Choice of Mounting Styles: IAP10 for compact light weight and direct-to-process mounting (bracket optionally available
  • Rugged & Dependable: Field-proven silicon strain gauge technology and corrosion-resistant epoxy finish
  • Superior Performance: Accuracy to ±0.05% of span and Ambient temperature effects to ±(0.03% URL+0.06%) span per 28°C (50°F)
  • Best in the industry - 5 year warranty

FEATURES

  • Silicon strain gauge sensors successfully field proven in many thousands of installations.
  • Simple, elegant sensor packaging with very few parts; achieves exceptionally high reliability.
  • Aluminum housing has durable, corrosion resistant epoxy finish; 316 ss housing also available; both meet the ratings of NEMA 4X and IEC IP66.
  • Remote configuration or locally via the optional LCD Indicator.
  • Can be provided with numerous configurations of direct connect or remote mount seals.
  • HART protocol allows multidrop topology.
  • SIL2-Certified transmitter offered as an option.
  • The IAP10 and IGP10 are offered with integral process connections for sanitary, and pulp and paper installations. Also, the IGP10 is offered for high gauge pressure applications to 52, 105, or 210 MPa (7500, 15,000, or 30,000 psi).
  • Sensor wetted parts materials include Co-Ni-Cr, 316L ss, and nickel alloy (equivalent to Hastelloy (1)); additionally, Monel, tantalum, and gold-plated 316L ss sensors are offered for the IAP20/IGP20.
  • CE marked; complies with applicable EMC, ATEX, and PED European Union Directives.
  • Multi-marking available for ATEX, CSA, and FM intrinsically safe applications. User determines and permanently marks the certification to be applied.
  • Complies with NAMUR NE 21 interference immunity requirement, and NAMUR NE 43 analog output overrange and underrange annunciations.
  • Complies with electromagnetic compatibility requirements of European EMC Directive 2004/108/EC by conforming to following EN and IEC Standards: EN 61326-1, and IEC 61000-4-2 through 61000-4-6.
  • Meet numerous requirements for hazardous locations. Versions available to meet Agency flameproof and zone requirements.
  • Dual Seal certified by CSA to meet ANSI/ ISA 12.27.01-2003 requirements.
  • Numerous mounting bracket set options. Many other options and accessories offered.
  • Standard 5-year warranty.

 

I/A Series® PRESSURE TRANSMITTER FAMILY

The I/A Series Electronic Pressure Transmitters are a complete family of d/p Cell®, gauge, absolute,   multirange, multivariable, and premium performance transmitters, as well as transmitters with remote or direct connect pressure seals, all using field-proven silicon strain gauge sensors and common topworks.

OPTIONAL LCD DIGITAL INDICATOR

This is a two-line digital indicator with on-board pushbuttons that displays the measurement with a choice of units. The pushbuttons allow zero and span adjustments, as well as local configuration without the need for a Communicator or PC-based Configurator.

MODULAR ELECTRONICS

A common HART electronics module is used for all I/A Series HART Pressure Transmitters. Also, because all configuration and calibration data is stored in the sensor, you can replace a HART module with another HART module without transmitter reconfiguration or recalibration.
Furthermore, if your needs change, the transmitter modular design allows easy migration to other standards, including FoxComTM, FOUNDATIONTM fieldbus, and Analog 4 to 20 mA or 1 to 5 V dc.

HART Communication Protocol Version (-T Electronics)

4 to 20 mA with HART communications. Allows direct analog connection to common receivers while still providing full digital communications using a Communicator, PC-based Configurator, or optional LCD Indicator.
HART Communicators can be upgraded with software to accommodate these transmitters. Also, Invensys will make use of the HART Foundation library of registered DDs (Device Descriptors), and reload a Communicator if the user desires to keep another supplier's DD along with the Foxboro DD.
In addition to HART, Invensys also offers transmitters with other protocols as described below.

FOUNDATION Fieldbus Version (-F Electronics)

This is a FISCO/FNICO compliant all digital, serial, two-way communication system which interconnects field devices such as transmitters, actuators, and controllers. It is a local area network (LAN) with built-in capability to distribute control across the network.

Analog Output Version (-A Electronics)

Provides a 4 to 20 mA analog output and includes a standard LCD Indicator to provide transmitter configuration directly from on-board pushbuttons.

Analog Output Version (-V Electronics)

A low power, low voltage transmitter that draws no more than 3 mA, and transmits a 1 to 5 V dc output signal. As with the -A version, it includes a standard LCD Indicator. Refer to PSS 2A-1C13 D.

HART Intelligent Module Configured for 4 to 20mA Output

Measurements and diagnostics are available from the HART Communicator connected to the two-wire loop carrying the 4 to 20 mA measurement signal by using a bidirectional digital signal superimposed on the 4 to 20 mA current signal.
Multiple measurements are transmitted digitally, including not only the primary measurement in pressure units, but also the electronics temperature and sensor temperature which can be used to monitor external heat tracing equipment. Complete transmitter diagnostics are also communicated. Configuration and reranging can be accomplished with the Communicator, PC-based Configurator, or the optional LCD Indicator with pushbuttons.

HIGH PERFORMANCE

Both direct-connected and bracket-mounted transmitters utilize microprocessor-based correction to achieve both excellent accuracy and ambient temperature compensation.

OPTIONAL SIL2 TRANSMITTERS

Modern industrial processes tend to be technically complex and have the potential to inflict serious harm to persons or property during a mishap. The IEC 61508 standard defines safety as “freedom from unacceptable risk.” SIL2 pressure transmitters with HART communication protocol, in conjunction with Triconex Safety Systems, provide integrated solutions for safety and critical control applications. The integrated solution is certified as interference-free from the 4 to 20 mA loop; this guarantees the integrity of the safety system and the safety of the controlled process. The integrated design allows uninterrupted operation of the safety function, while allowing access to device level information via HART commands. The solution permits interface of device diagnostics with asset management systems without compromising functional safety. Select Option -S2 for a SIL2-certified HART Transmitter. A copy of the certification is available via Auxiliary Specification (AS) Code CERT-S.

MULTIDROP COMMUNICATIONS

Point-to-point or multidrop topologies are permitted. Multidropping is the connection of several transmitters to a single communications line. Communications between the host computer and transmitters takes place digitally with the analog output of the transmitter fixed. Up to fifteen transmitters can be connected on a single twisted pair of wires or over leased telephone lines.

CHOOSE MOUNTING CONFIGURATION NEEDED

Direct Connected Transmitters (Models IAP10 and IGP10)
These transmitters are light weight and easy-to-install. They use 316L ss or nickel alloy (equivalent to Hastelloy®) process connections, and a choice of either 316L ss, Cobalt-Nickel-Chrome, or nickel alloy for the sensing diaphragm. See Direct-Connected Transmitters section.
Bracket-Mounted Transmitters (Models IAP20 and IGP20)
These transmitters offer a large selection of corrosion resistant process covers and sensing diaphragm materials. They are suitable for applications requiring low spans, vacuum service, and high overrange pressure.

EASE OF INSTALLATION

Rotatable Topworks allows transmitter installation in tight places, allows indicator to be positioned in preferred direction, and eases field retrofit. Two Conduit Entrances offer a choice of entry positions for ease of installation and self-draining of condensation regardless of mounting position  and topworks rotation. Wiring Guides and Terminations provide ease of wire entry and support, plenty of space to work and store excess wire, and large, rugged screw terminals for easy wire termination.

EXCEPTIONAL VALUE

The combination of small size, light weight, direct mounting, standard materials,and wide measurement capability with high performance make this an exceptionally cost effective solution for process pressure measurement.

DIRECT PROCESS MOUNTING

Because of their light weight and external threaded connection, these transmitters can be installed directly on process piping without mounting brackets.However, for unique requirements, an optional bracket is offered and connection can be made to the standard 1/4 NPT internal thread.

WIDE RANGEABILITY

Three absolute pressure versions are offered to allow spans from 7 to 21,000 kPa (1 to 3,000 psi), and four gauge pressure versions are offered to allow spans from 7 to 42,000 kPa (1 to 6,000 psi). Refer to IGP20 Transmitter for gauge pressure vacuum service.

316L ss, NICKEL ALLOY, AND Co-Ni-Cr PROCESS WETTED PARTS

With process connection of 316L ss or nickel alloy (equivalent to Hastelloy®) and sensor diaphragm available in either 316L ss, nickel alloy, or highly corrosion resistant Co-Ni-Cr, this transmitter is an excellent choice for the vast majority of process pressure measurements.

FLAMEPROOF DESIGN

The IAP10 and IGP10 flameproof versions are designed to meet Agency flameproof and zone requirements.

HIGH GAUGE PRESSURE VERSIONS

Three high gauge pressure versions with URLs of 52,105, and 210 MPa (7,500, 15,000, and 30,000 psi)are available in the IGP10 line.

SANITARY AND PULP AND PAPER VERSIONS

These transmitters are also available with integral process connections for use in sanitary, and pulp and paper installations. See PSS 2A-1C13 K and PSS 2A-1C13 L, respectively.

BRACKET-MOUNTED TRANSMITTER – IAP20 AND IGP20

SENSOR CORROSION PROTECTION

Choice of 316L ss, Co-Ni-Cr, nickel alloy (equivalent to Hastelloy®), Monel, Gold-Plated 316L ss, andTantalum materials. High corrosion resistance of CoNi-Cr(TI037-078)means long service life in many difficult applications without the extra cost for exotic materials.Also see TI 37-75b for process applicability with Co-Ni-Cr and other process wetted parts materials.

WIDE RANGEABILITY

Gauge pressure measurement spans may be as low as 0.12 kPa (0.5 inH O) to as high as 35 MPa (5000 psi) by choosing one of only six sensors, and absolute pressure measurement spans may be as low as 0.87 kPa (3.5 in H 2 O) to as high as 21 MPa (3000 psi) by choosing one of only four sensors. This provides exceptional measurement range capability with a minimum of versions.

HIGH GAUGE PRESSURE VERSIONS

Three high gauge pressure versions with URLs of 52,105, and 210 MPa (7,500, 15,000, and 30,000 psi)are available in the IGP10 line.

VACUUM SERVICE

A lower range limit of -100 kPa (-14.7 psi, -1 bar or kg/cm2 ) means that vacuum measurements are easily handled with the versatile IGP20 Gauge Pressure transmitter.

PROCESS CONNECTOR

Removable, gasketed process connector (Figure 2)allows a wide range of selections, including 1/4 NPT,1/2 NPT, Rc 1/4, Rc 1/2, and weld neck connections. For highly corrosive chemical processes, a 1/2 NPTpvdf (Kynar) insert, as shown in Figure 3, is installed in the HI-side 316 ss cover and is used as the process connector. In these applications, tantalum is used as the sensor diaphragm material.

EASE OF MOUNTING TWO-VALVE MANIFOLD

Optional two-valve manifold to isolate transmitter, and vent pressure, is easily mounted directly to transmitter.

FLAMEPROOF DESIGN

The transmitters are designed to meet Agency flameproof and zone requirements.

FUNCTIONAL SPECIFICATIONS

Output Signal and Configuration

Output is 4 to 20 mA with digital HART communications. For multidrop applications, the mAsignal is fixed at 4 mA to provide power to the device. Configurable using the HART Communicator, PCbased Configurator, or optional LCD Indicator with on-board pushbuttons.

Electronics and Sensor Temperatures

Readable from the Communicator or PC-based Configurator. Measurement is transmitter temperature, at the sensor and the electronic module, not necessarily process temperature.

Field Wiring Reversal

No transmitter damage.

Suppressed Zero and Elevated Zero

Suppressed or elevated zero ranges are acceptable as long as the Span and Range Limits are not exceeded (elevated zero applicable to IGP20 only).

Zero and Span Adjustments

Zero and span adjustments can be initiated using the Communicator, a PC-based Configurator, or the optional LCD with on-board pushbuttons.

Write Protect Jumper

Can be positioned to lock out all configurators from making transmitter database changes. This makes transmitter suitable for Safety Shutdown System Applications that require this feature.

Supply Voltage Requirements and External Loop Load Limitations

Nominal minimum supply voltage is 11.5 V dc. This value can be reduced to 11 V dc by using a plug-in jumper across the test receptacles in the field wiring compartment terminal block as shown in the Physical Specifications section.

Order Code

Description       Model
I/A Series, Electronic, Direct Connected Absolute Pressure Transmitter IAP10 (a)
I/A Series, Electronic, Direct Connected Gauge Pressure Transmitter IGP10 (a)
Electronics Versions and Output Signal        
Intelligent; Digital HART and 4 to 20 mA dc (Version -T) -T
Structure Code - Select from one of the following six groups:  
1. Transmitter Only (no seals)        
Process Connection Sensor Sensor Fill Fluid Connection Type  
316L ss Co-Ni-Cr Silicone 1/2 NPT External Thread, 1/4 NPT Internal Thread 20
316L ss Co-Ni-Cr Inert 1/2 NPT External Thread, 1/4 NPT Internal Thread 21
316L ss 316L ss Silicone 1/2 NPT External Thread, 1/4 NPT Internal Thread 22
316L ss 316L ss Inert 1/2 NPT External Thread, 1/4 NPT Internal Thread 23
316L ss Nickel alloy (s) Silicone 1/2 NPT External Thread, 1/4 NPT Internal Thread 30
316L ss Nickel alloy (s) Inert 1/2 NPT External Thread, 1/4 NPT Internal Thread 31
2. Transmitter Prepared for Foxboro Model Coded Seals (b)  
Transmitter Prepared for Foxboro Direct Connect Seal; Silicone Fill in Sensor (c) D1
Transmitter Prepared for Foxboro Direct Connect Seal; Inert Fill in Sensor (IGP10 only) (c) D2
Transmitter Prepared for Foxboro Remote Mount Seal; Silicone Fill in Sensor (d) S3
Transmitter Prepared for Foxboro Remote Mount Seal; Inert Fill in Sensor (IGP10 only) (d) S4
3. Transmitters Prepared for non-Foxboro Seals  
Transmitter Prepared for Remote Seal; Silicone Fill in Sensor (e) SC
Transmitter Prepared for Remote Seal; Inert Fill in Sensor (f) SD
4. Flameproof Transmitter Only (no seals)  
Process Connection Sensor Sensor Fill Fluid Connection Type  
316L ss 316L ss Silicone 1/2 NPT External Thread, 1/4 NPT Internal Thread 52
316L ss 316L ss Inert 1/2 NPT External Thread, 1/4 NPT Internal Thread 53
316L ss Nickel alloy (s) Silicone 1/2 NPT External Thread, 1/4 NPT Internal Thread 60
316L ss Nickel alloy (s) Inert 1/2 NPT External Thread, 1/4 NPT Internal Thread 61
Nickel alloy (s) Nickel alloy (s) Silicone 1/2 NPT External Thread, 1/4 NPT Internal Thread 62
Nickel alloy (s) Nickel alloy (s)Description Inert 1/2 NPT External Thread, 1/4 NPT Internal Thread 63
5. Flameproof Transmitter Prepared for Foxboro Model Coded Seals (b)  
Flameproof Transmitter Prepared for Direct Connect Seal; Silicone Fill in Sensor (c) D5
Flameproof Transmitter Prepared for Direct Connect Seal; Inert Fill in Sensor (IGP10 only) (c) D6
Flameproof Transmitter Prepared for Remote Mount Seal; Silicone Fill in Sensor (d) S5
Flameproof Transmitter Prepared for Remote Mount Seal; Inert Fill in Sensor (IGP10 only) (d) S6
6. Flameproof Transmitter Prepared for non-Foxboro Seals  
Flameproof Transmitter Prepared for Remote Seal; Silicone Fill in Sensor (e) SH
Flameproof Transmitter Prepared for Remote Seal; Inert Fill in Sensor (f) SJ
         
Span Limits - Absolute or Gauge Pressure Units, as Applicable        
MPa psi bar or kg/cm2    
0.007 and 0.21 1 and 30 0.07 and 2.1   C
0.07 and 2.1 10 and 300 0.7 and 21   D
0.7 and 21 100 and 3000 7 and 210   E
14 and 42 2000 and 6000 140 and 420 (IGP10 only)   F
         
Conduit Connection and Housing Material  
1/2 NPT Conduit Connection, Aluminum Housing 1
PG 13.5 Conduit Connection, Aluminum Housing (With Electrical Safety Codes E, D, M, N, and P only) 2
1/2 NPT Conduit Connection, 316 ss Housing 3
PG 13.5 Conduit Connection, 316 ss Housing (With Electrical Safety Codes E, D, M, N, and P only) 4
M20 Conduit Connection, Both Sides, Aluminum Housing (With Electrical Safety Codes E, D, M, N, and P only) 5
M20 Conduit Connection, Both Sides, 316 ss Housing (With Electrical Safety Codes E, D, M, N, and P only) 6
         
Electrical Safety (Also See Electrical Safety Specifications Section)  
ATEX II 1 GD, EEx ia IIC, Zone 0 E
ATEX II 2 GD, EEx d IIC, Zone 1 (g)(j) D
ATEX II 3 GD, EEx nL IIC, Zone 2 N
ATEX Multiple Certifications (includes ATEX Codes E and N)  
(See Electrical Safety Specifications section for user marking)  
ATEX Multiple Certifications (includes ATEX Codes E, D, and N) (g)(j) P
(See Electrical Safety Specifications section for user marking)  
CSA Certifications: (h) C
Division 1 intrinsically safe, explosionproof, dust-ignitionproof  
Zone certified Ex ia IIC and energy limited Ex nA II  
Division 2, Classes I, II, and III  
CSA zone certified flameproof Ex d IIC; also all certifications of Code C above (g)(j) B
FM Approvals: (h) F
Division 1 intrinsically safe, explosionproof, dust-ignitionproof  
Zone approved AEx ia IIC  
Division 2 nonincendive, Classes I, II, and III  
FM approved flameproof AEx d IIC; also all approvals of Code F above (g)(j) G
IECEx intrinsically safe, Ex ia IIC T
IECEx protection n, Ex nL IIC U
IECEx flameproof, Ex d IIC (g)(j) V
Multi-marked for ATEX, CSA, and FM Intrinsically Safe Applications only (q) W
         
Optional Selections  
Mounting Bracket Set (i)  
Painted Steel Bracket with Plated Steel Bolts, 1/2 NPT (with Conduit Connection Codes 1 and 3 only) -M1
Stainless Steel Bracket with Stainless Steel Bolts, 1/2 NPT (with Conduit Connection Codes 1 and 3 only) -M2
Painted Steel Bracket with Plated Steel Bolts, PG 13.5 (with Conduit Connection Codes 2 and 4 only) -M3
Stainless Steel Bracket with Stainless Steel Bolts, PG 13.5 (with Conduit Connection Codes 2 and 4 only) -M4
Painted Steel Bracket with Plated Steel Bolts, M20 (with Conduit Connection Codes 5 and 6 only) -M5
Stainless Steel Bracket with Stainless Steel Bolts, M20 (with Conduit Connection Codes 5 and 6 only) -M6
         
Digital Indicator with Pushbuttons        
Digital Indicator, Pushbuttons, and Window Cover -L1
         
Vent Screw and Block & Bleed Valve  
316 ss Vent Screw in Process Connection (Not with Structure Codes 32 or 33, or Pressure Seals) -V1
Block and Bleed Valve, Carbon Steel (Not with Pressure Seals) -V2
Block and Bleed Valve, 316 ss (Not with Pressure Seals) -V3
Block and Bleed Valve, 316 ss w/Monel Trim (Not with Pressure Seals) -V4
         
Conduit Thread Adapters  
Hawke-Type 1/2 NPT Cable Gland for use with Conduit Connection Codes 1 and 3 only (l) -A1
Plastic PG 13.5 Cable Gland for use with Conduit Connection Codes 2 and 4 only (m) -A2
M20 Connector for use with Conduit Connection Codes 1 and 3 only (l) -A3
Brass PG 13.5 Cable Gland (Trumpet-Shaped) for use with Conduit Connection Codes 2 and 4 only (m) -A4
         
Electronics Housing Features  
External Zero Adjustment -Z1
Custody Transfer Lock and Seal -Z2
External Zero Adjustment and Custody Transfer Lock and Seal -Z3
         
Custom Factory Configuration  
Full Factory Configuration (Requires Configuration Form to be filled out)       -C2
         
Cleaning and Preparation  
Unit Degreased - for Silicone Filled Sensors Only (Not for Oxygen/Chlorine Service, Option -V1, or Pressure Seals) -X1
Cleaned and Prepared for Oxygen Service - for Inert Filled Sensors Only (Not with Option -V1, or Pressure Seals) -X2
Cleaned and Prepared for Chlorine Service - with Structure Code 33 Only (Not with Option -V1, or Pressure Seals) -X3
         
SIL2 Transmitters  
SIL2-Certified HART Transmitter -S2
         
Instruction Books (Common MI, Brochure, and Full Documentation Set on CD-ROM is Standard)  
Without Instruction Book and CD - Only “Getting Started” Brochure is supplied -K1
         
Miscellaneous Optional Selections  
G 1/2 B Manometer Process Connection (Not Available with Option -V1 or Pressure Seals) -G
Low Temperature Operative Limit of Electronics Housing Extended Down to -50°C (-58°F) (r) -J
Not available with sensors and seals with Inert fill; Structure Codes 78 and 79; and  
DIN Options -D2, -D4, -D6, and -D8 (n)  
R 1/2 Process Connection (1/2 NPT to R 1/2 Adapter) (p) -R
Supplemental Customer Tag (Stainless Steel Tag wired onto Transmitter) -T

Absolute pressure range
IAP10, IAP10S, IAP20,
Differential pressure range
IDP10, IDP15, IDP25, IDP31, IDP32, IDP50
Gauge pressure range
IGP10, IGP10S, IGP20, IGP25, IGP50, IGP60
Multi variable transmitter range
IMV25, IMV30, IMV31

 

If you require further information on this product or would like a quotation, please contact dp-flow on:

Supplied by DP-Flow