Skip to main content

Orifice Plate MES

Orifice Plate with Single Pressure Tapping Series in all Welded Construction MES

orifice assembly all welded high pressure MES

Manufactured by  emco controls

EMCO orifice plates are used as primary elements in flow measurement of steam, liquid, and gas according to the differential pressure principle.

Design and calculation standards :

  • ISO 5167-2, ASME MFC-3M, DIN 19215, Shell Flow Meter Engineering Handbook, AGA no. 3
  • Sizes : DN 50 - 1000 according to DIN 2402
  • Pressure rating : PN 10 - 400, 150 - 2500 lbs
  • Plate thickness : 10 mm
  • Vent or drain hole : On request
  • Material : Carbon steel P235GH, AISI 316, 16Mo3, 13CrMo4-5, 10CrMo9-10, WB 36, X20CrMoV121, other materials on request
  • Mounting style : Weld ends according to DIN 2559 or ANSI B16.25
  • Orifice plate shapes : Square edge concentric, square edge eccentric, conical, 1/4 circle, segment. The plate is bevelled on the down stream side except for 1/4 circle orifice plate.
  • Pressure taps : Ø 21.3 mm, 24 mm, 26.9 mm, 1⁄2" BSP male, 1⁄2" NPT male
  • Tap lengths : 150 mm, others on request.
  • Tap location : Tap location for steam flow: 180°. At least 45° apart for liquid and gas. To be stated with order
  • Marking : The orifice plate is marked with "+" and "-" and flow direction.
  • Accessories : single and double shut-off valves and condensing chambers for steam flow measurement
  • Technical Data
  • Accuracy : +/- 0,5 % for β < 0,6 and equal to β for β values above 0,6
  • Pressure loss : Depending on β, for β equal to 0,6 : ca. 60 % of the differential pressure measured
  • Limits for Reynolds No : Re > 1260 x β2 D according to ISO 5167, 2000 < Re < 108 according to ASME MFC-3M?

orifice plate shapes

Dimensions

All dimensions in mm

DN Ø Inner pipe Upstream length Total length Upstream length Total length
    ISO 5167 ISO 5167 DIN 19215 DIN 19215
50 45 - 57 115 230 150 250
65 58 - 72 145 290 180 300
80 73 - 90 180 360 230 350
100 91 - 112 225 450 280 400
125 113 - 137 275 550 350 500
150 138 - 162 325 650 400 600
(175) 163- 187 375 750 470 700
200 188 - 225 450 900 570 800
250 226 - 275 550 1100 690 1000
300 276 - 325 650 1300 820 1200
350 326 - 375 750 1500 950 1400
400 376 - 425 850 1700 1050 1500
450 426 - 475 950 1900 1200 1700
500 476 - 550 1100 2200 1370 2000
600 551 - 650 1300 2600 1500 2000
700 651 - 750 1500 3000 1500 2000
800 751 - 850 1700 3400 1500 2000
900 851 - 950 1900 3800 1500 2000
1000 951 - 1100 2200 4400 1500 2000

Works with:-

Differential pressure transmitters:-IDP10; IDP15; IDP25; IDP31; IDP50
And all our Absolute Pressure and Gauge Pressure transmitters, Temperature sensors and mass flow computers.
MultiVariable Transmitters :- IMV25, IMV30

 
 